Why a Resettable Fuse Cannot Trip Instantly

Resettable fuse selection is well covered online, in tutorials both long and short, and anyone with patience can learn the basics. Here we highlight a few selection mistakes that are easy to make, so that customers can avoid them and the losses they cause.
 
 
Customers often come to us with a request like this: I need a resettable fuse that trips immediately when the current exceeds X, my product runs at X under normal load, and so on for the other parameters. We have to point out that no fuse can trip that fast. A fuse normally begins to protect at about twice the normal operating current. This is deliberate: it keeps the inrush current at start-up from melting the fuse, which would otherwise cause nuisance tripping. (Related reading: Applications of Resettable Fuses in Portable Power Tools)
 
 
On the other hand, judging by the device itself, a resettable fuse trips a little more slowly than a one-time fuse. That is why resettable fuse datasheets usually specify a trip at five times the current, with a maximum time of a few seconds.


Leaded resettable fuse
 
 
Inside a resettable fuse the materials are PE, carbon black and copper foil. Under normal conditions the carbon black particles are linked in an orderly chain through the PE, and the internal resistance is the normal value. When the circuit current rises, Joule heating (Q = I2t) adds heat; once the heat produced reaches 130 C, enough to melt the PE, the carbon particles become disordered and the resistance rises. By Ohm's law, I = U/R, the voltage is unchanged while the resistance grows, so the current falls. The circuit is protected and the current returns to its normal level.
 
 
The formulas above show that the protection time of a resettable fuse is proportional to the circuit current. When the current only slightly exceeds X, the heat produced cannot reach the 130 C needed to melt the PE, so the fuse does not protect. When the current exceeds X by a factor of two or more, the heat reaches 130 C quickly and the fuse trips at once.
 
 
That explains why a resettable fuse cannot protect a device instantly. If anything is still unclear, leave us a message on the contact page and we will reply as soon as possible. (Recommended reading: Protecting the Motor of an Automotive Central Locking System with a Resettable Fuse)