SMD Resettable Fuse Test Guide

Recently many customers have reported questions about testing SMD resettable fuses: whatever they measure, the data comes out wrong. Today we have put together the relevant background to answer these questions.

SMD resettable fuse

SMD resettable fuse
 
The test procedure is as follows:
 
 
1.  Initial resistance Rimin: unpack the fuse, take it out and measure its internal resistance;
 
 
2.  Soldering: solder the fuse onto a PCB by reflow soldering. The PCB carries lead wires so that electrical tests can be performed (as shown above);
 
 
3.  Holding current Ihold test: use a DC constant-voltage constant-current source. Set the voltage to Vmax and the current to the holding current Ihold as specified in the datasheet, then energize for 15 minutes. (Related reading: SMD resettable fuse product information)
 
 
4.  Tripping current Itrip test: use a DC constant-voltage constant-current source. Set the voltage to Vmax and the current to the tripping current Itrip as specified in the datasheet, then energize for 5 minutes;
 
 
5.  R1max test: let the tripped fuse cool for 1 hour, then measure its internal resistance.
 
 
Acceptance criteria:
 
 
1.  Testing is carried out at room temperature (25°C), free of light and heat radiation;
 
 
2.  The initial resistance Rimin must be within the range given in the datasheet;
 
 
3.  The fuse passes if it does not trip within 15 minutes at Ihold;
 
 
4.  The fuse passes if it trips within 5 minutes at Itrip;
 
 
5.  After tripping, the internal resistance R1max must be within the range given in the datasheet. (Recommended reading: Common parameter definitions for SMD fuses)
 
 
The above is a short test guide for SMD resettable fuses. If you have further questions, contact our online sales staff or talk directly to your account manager, and we will work out a more detailed solution for you.