In an earlier article we looked in detail at how to test SMD resettable fuses. At the request of customers we have since collected some of the questions that come up most often during SMD resettable fuse testing and answered them below.
 
 
Q: Our lab only has a multimeter. Can it be used to measure internal resistance?
 
 
A: A dedicated micro-ohmmeter (such as a Hioki 3540) is recommended. Without one, a multimeter can be used for a rough measurement.
 
 
Q: Our lab has no dedicated power supply. Can an ordinary constant-voltage constant-current source be used for testing?
 
 
A: Yes, an ordinary constant-voltage constant-current source can be used.
 
 
Q: Our lab has no PCB. Can the fuse be tested directly on a bench top? (Related reading: SMD Resettable Fuse Test Guide)
 
 
A: Whether a fuse protects at all comes down to this: the heat it absorbs must exceed the heat it dissipates. Heat builds up inside the fuse and, once it reaches a certain level, the fuse trips. Testing on a PCB reproduces the real operating environment of the fuse. Testing on a wooden bench, a plastic sheet or a cloth mat changes the heat exchange and therefore the heat dissipation, which compromises the accuracy of the measurement.
 
 
Q: Our lab has no SMT equipment. Can the fuse be hand-soldered?
 
 
A: Polymer is one of the main materials in a resettable fuse. Heat changes its microscopic state and thereby the internal resistance of the fuse. A soldering iron can exceed 350 °C, and prolonged exposure will alter the properties of the fuse, so reflow soldering is recommended. Where hand soldering is unavoidable, complete the joint in the shortest possible time to minimise the effect of the temperature field on the fuse.
 
 
Q: The leakage current through the fuse reaches several hundred mA during testing. What is happening?
 
 
A: In the tripped state the power the fuse can handle is fixed. The higher the voltage across it, the lower the leakage current; conversely, the lower the voltage, the higher the leakage current. (Related reading: Why an SMD fuse sometimes shows a high resistance without opening)


 
Resettable fuse
 
Q: I was testing a fuse with Vmax 33 V and Ihold 1 A. I set the voltage to 33 V and the current to 1 A, then touched the probe to the fuse and it tripped at once. Why?
 
 
A: With the test probes not yet connected to the fuse, raising the supply to a high voltage accumulates a large amount of charge across the probes. The moment they touch the fuse a discharge path is formed, the charge is released abruptly as an inrush current, and spark discharge may even occur. The fuse then absorbs a large amount of energy in a very short time and trips; in severe cases it smokes, arcs and is destroyed. The correct procedure is to connect the fuse into the test circuit at a low voltage (3-4 V) first and then raise the voltage gradually, or to control the circuit with a switch.
 
 
Q: The fuse has already been reflow-soldered onto the board and was then removed by hand soldering. Can it still be tested?
 
 
A: No. Once mounted, the internal material of the fuse has already undergone one thermal deformation, and a second reflow or wave soldering pass will damage it further and affect its electrical performance. Removing it by hand soldering involves a higher temperature and is hard to control in time, so the fuse is damaged a second time.
 
 
Those are some of the questions that can arise when testing SMD resettable fuses. If anything is still unclear, contact one of our online sales engineers at Shenzhen Joincircuit Industrial Co., Ltd. (JDT Fuse), call the engineer responsible for your area for a one-to-one discussion, or talk to our technical staff; leave your question on the Contact Us page and we will answer it as soon as possible. (Recommended reading: Shenzhen 1206 Series Single-Blow Fast-Acting and Time-Lag SMD Fuses)