Rated zero-power resistance R25: zero-power resistance is the resistance measured at a given temperature with so little power applied to the PTC thermistor that the change in resistance caused by that power is negligible. The rated zero-power resistance is the value measured at an ambient temperature of 25 °C.
Temperature coefficient α: the temperature coefficient of a PTC thermistor is defined as the relative change in resistance caused by a change in temperature. The larger the coefficient, the more sensitive the thermistor is to temperature change. α = (lgR2 - lgR1) / lge(T2 - T1)
Rated voltage VN: the rated voltage is the supply voltage below the maximum operating voltage Vmax. Usually Vmax = VN + 15 [%]
Surface temperature Tsurf: surface temperature Tsurf is the temperature of the PTC thermistor surface when the part has been held at the specified voltage and in thermal equilibrium with its surroundings for a long period.
Operating current Ik: a current through a PTC thermistor that is large enough for self-heating to raise its temperature above the Curie temperature is called the operating current. The lowest such current is the minimum operating current.
Non-operating current INk: a current through a PTC thermistor that is not large enough for self-heating to raise its temperature above the Curie temperature is called the non-operating current. The highest such current is the maximum non-operating current. (Recommended reading: Operating characteristics of polymer thermistors)