How to Select a Varistor (VDR): Key Parameters and Precautions

Before choosing a VDR varistor, you should first understand the following technical parameters: the nominal voltage is the voltage across the varistor at a specified temperature and DC current; the leakage current is the current through the varistor at 25℃ with the maximum continuous DC voltage applied; and the clamping voltage is the peak voltage that appears across the varistor when an 8/20 current pulse passes through it  .
 
 
The surge current rating is the peak current at which the specified 8/20μs pulse current waveform is applied. Surge environment parameters include the maximum surge current Ipm (or the maximum surge voltage Vpm together with the surge source impedance Zo), the surge pulse width Tt, the minimum interval Tm between two consecutive surges, and the total number of surge pulses N over the intended service life of the varistor. (Related reading: Operating characteristics of polymer thermistors)
 
 
In general a VDR varistor is connected in parallel with the device or equipment it protects. Under normal conditions the DC or AC voltage across the varistor should be below the nominal voltage, and even at the worst supply fluctuation it should not exceed the maximum continuous operating voltage chosen from the ratings; the nominal voltage that corresponds to that maximum continuous operating voltage is the value to select. For overvoltage protection applications the varistor voltage must be higher than the actual circuit voltage and is normally selected with the following formula: VmA=av/bc, where:
 
 
a is the circuit voltage fluctuation coefficient; v is the circuit DC working voltage (the RMS value for AC);
 
 
b is the varistor voltage tolerance; c is the ageing coefficient of the component;
 
 
The VmA obtained this way is 1.5 times the DC working voltage  , and for AC operation the peak value must also be taken into account, so the result should be multiplied by 1.414. (Related reading: How polymer thermistors work)
 
 
In addition, the following points must be observed when selecting a part:
 
 
(1) Make sure that even at the largest voltage fluctuation the continuous operating voltage cannot exceed the maximum permitted value, otherwise the service life of the varistor will be shortened;
 
 
(2) When a varistor is used between a supply line and earth, poor earthing sometimes raises the line-to-earth voltage, so a varistor with a higher nominal voltage than in line-to-line applications is normally used  .
 
 
The surge current absorbed by the varistor should be lower than the maximum discharge current of the product. (Recommended reading: Which process steps improve the stability of NTC thermistors)