Key Considerations When Selecting a Fuse

Fuse selection: which points need attention? This is a question many people have. Selecting a fuse is not simply a matter of determining the model and ratings from the operating current and voltage; several issues must be considered, and once the parameters of the circuit are known the fuse should be chosen in terms of the following aspects: normal current, breaking current (the current and time at which breaking is expected), open-circuit voltage, short-circuit current, impulse current (the current, duration and number of impulses that are not to cause breaking) and ambient temperature.
 
 
1) Normal current: first of all, the normal current flowing through the fuse in the circuit concerned must be known. As a rule a derating factor is set in advance, and the selection then follows this principle: the normal current must be lower than the product of the rated current and the derating factor. (Related reading: overcurrent protection of projectors with resettable PPTC fuses)
 
 
2) Breaking current: according to UL requirements, a fuse should break quickly at twice its rated current. In most cases, however, reliable breaking calls for a breaking current above 2.5 times the rated current. If the breaking time matters, the time-current characteristic curves supplied by the manufacturer must also be consulted.
 
 
3) Open-circuit voltage: the open-circuit voltage should generally be selected below the rated voltage. A fuse rated at DC 24 V used in an AC 100 V circuit, for example, may ignite or rupture.
 
 
4) Short-circuit current: the maximum current flowing when the circuit is short-circuited is called the short-circuit current. Every fuse has a specified rated breaking capacity, and care must be taken not to let the short-circuit current exceed it. A fuse with too low a breaking capacity may rupture or start a fire. (Related reading: overcurrent protection of explosion-proof luminaires with resettable PPTC fuses)
 
 
5) Impulse current: observe the impulse current waveform (pulse current waveform) and calculate its energy from the I2t value (Joule integral). Impulse currents of different magnitude and number affect the fuse differently. The ratio of the impulse current I2t to the single-pulse breaking I2t determines how many impulse cycles the fuse can withstand.
 
 
Which issues require attention when selecting a fuse? We hope this brief introduction has given you a clearer understanding of fuse selection. If anything remains unclear, leave a message for us on the Contact Us page and we will reply as soon as possible. (Recommended reading: how to select a fuse and what to watch out for in fuse selection)