An Introduction to Over-Current Protection
An introduction to over-current protection - over-current protection (OCP) is a protection method in which the protective device operates once the current exceeds a preset maximum. When the current flowing through the protected equipment exceeds a value set in advance, the device picks up and uses a time delay to ensure selectivity, tripping the circuit breaker or giving an alarm signal.
An introduction to over-current protection - when a phase-to-phase short circuit, an abnormal rise in load or a fall in insulation level occurs in the grid, the current rises sharply and the voltage drops. Over-current protection meets the selectivity requirements of the line by setting the pick-up current of the current relay. (Related reading: Resettable fuse application cases)
When the fault current in a line reaches the pick-up value of the current relay, the relay operates and, to meet the selectivity requirements of the protection scheme, isolates only the faulted line: its contact starts the time relay, and after the preset delay the time-relay contact closes and energises the trip coil of the circuit breaker. The breaker trips, the faulted line is cleared, the signal relay is started at the same time, the indicator flag drops and the lamp or audible alarm is switched on.
Over-current protection - how it works: when an unexpected condition such as a short-circuited load, an overload or a failure of the control circuit occurs, the current through the switching transistor of the regulator becomes excessive, its power dissipation rises and it heats up. Without an over-current protection device a high-power switching transistor can be destroyed, so over-current protection is common in switching regulators.
The most economical and simplest method is to use a fuse. A transistor has little thermal capacity, so an ordinary fuse usually gives no protection; fast-acting fuses are normally used. This method has the advantage of being easy to implement, but the fuse rating has to be selected to suit the safe operating area of the particular switching transistor, and its drawback is that the fuse has to be replaced frequently. (Related reading: Leaded resettable fuses)
An introduction to over-current protection - the current-limiting protection and current-cutoff protection commonly used in linear regulators can both be applied to switching regulators. However, because of the characteristics of a switching regulator, the output of such a protection circuit cannot drive the switching transistor directly; the over-current protection output must first be converted into pulse commands that control the modulator and thereby protect the switching transistor.
Over-current protection is normally implemented with a sense resistor connected in series with the circuit, which affects the efficiency of the supply, so it is mostly used in low-power switching regulators. In high-power switching supplies the sense resistor should be avoided as far as possible because of the power loss, so over-current protection is usually converted into over-voltage and under-voltage protection.
An introduction to over-current protection - that is a brief introduction to the principle of over-current protection. If you have any comments or suggestions, leave a message for us on the contact page and we will reply as soon as possible. (Recommended reading: What is over-current protection)