Rated Current vs. Tripping Current

A reader with the screen name “The King Sent Me to Patrol the Mountain” sent us an email: hello, I am a high school student and I sometimes tinker with the appliances at home. When I read technical material online I often come across the two terms rated current and tripping current. Do they mean the same thing? How are they related?
 
 
A specialist at Shenzhen Joincircuit Industrial Co., Ltd. answers: rated current and tripping current are not the same concept. Rated current is the current at which a fuse can operate continuously. Tripping current is, as the name suggests, the current at which the fuse operates, that is, the current at which it provides protection. Because a fuse is a safety-related component, it must obtain the relevant certifications before it can be manufactured and sold.
 
 
Safety standards generally require that a fuse carrying its rated current must not exceed a permitted temperature; UL, for example, specifies that at 100% of rated current the temperature must not exceed 75°C. The standards also set fairly strict requirements on the fusing time once the actual current exceeds the rated current. For one particular fuse, for instance, at 1.5 times rated current the fuse must carry the current for at least 60 minutes; at 2.1 times rated current it may carry it for at most 2 minutes; at 2.75 times rated current it must carry it for at least 400 ms and at most 10 s; and there are further fusing-time requirements at 4 times and 10 times rated current. (Related reading: How Fast Does a Resettable Fuse Respond and How Long Does It Take to Recover)
fuse
fuse
 
 
In addition, UL-specification fuses have low overload capability, so a current derating factor is applied (Frf = 0.75). For a 3 A application, disregarding the influence of other characteristics, a 4 A fuse should be chosen at minimum (3/0.75 = 4).
 
 
That covers the relationship between the rated current and the operating current of a fuse. If anything is still unclear, please leave a message for us on the Contact Us page and we will reply as soon as possible. (Recommended reading: Joincircuit Answers Questions About Thermal Fuses)