≡ Param Finder by package / current / voltage
伯恩斯MF-MSMF014-2 自恢复保险丝 0.14A 60V 1812封装
上一张
  • 伯恩斯MF-MSMF014-2 自恢复保险丝 0.14A 60V 1812封装
下一张

Bourns MF-MSMF014-2 Resettable Fuse 0.14A 60V 1812

0.14 A hold current, 60 V maximum voltage, 1812 (4532) package. Post-trip resistance is 6.5 Ω maximum, less than half th

Download

0

The MF-MSMF014-2 is a 1812 surface-mount resettable fuse that carries 0.14 A continuously and withstands 60 V maximum. It measures 4.5 × 3.2 mm, has gold-plated terminals and suits reflow soldering. UL, CSA and TÜV recognised, RoHS compliant. Commonly used for overcurrent protection on sensor supplies, communication interfaces and low-power modules in 24 V and 48 V systems.

Brand:BOURNS (Joincircuit is an authorised distributor)
Category:Resettable fuse / SMD, 1812 SMD (4532 mm)
Voltage:60 V; Current:hold 0.14 A; trip 0.34 A.

Specifications

ParameterValue
Hold current0.14 A
Trip current0.34 A
Maximum voltage60 V
Maximum fault current40 A
Initial resistance0.4 Ω
Post-trip max resistance6.5 Ω
Trip current / time1.5 A / 0.15 s
Dissipated power0.8 W
Package1812 SMD (4532 mm)

Temperature Derating

-40℃-20℃0℃23℃40℃50℃60℃70℃85℃
Hold current (A)0.230.190.170.140.120.10.090.080.06
Share of 23 °C rating164%136%121%100%86%71%64%57%43%

Product Description

What this product is

The MF-MSMF014-2 is a polymer resettable fuse placed between a supply and its load. Above its current limit the internal resistance rises and holds the loop current to a low value. Once the fault is cleared and the part cools, resistance falls and the circuit recovers by itself, so no board comes out for rework. At 0.14 A it suits signal and sensor circuits, where load current is small.

Dimensions and appearance

1812 package, 4532 in metric, 4.5 mm long, 3.2 mm wide and 0.75 mm high, identical to the 0.10 A and 0.20 A parts of this series. Gold-plated terminals, black body, model code and production lot marked on top. Supplied on tape and reel for pick-and-place; hand soldering is also suitable.

How it works

It sits in series in the loop. At 0.14 A its own resistance is 0.40 Ω, giving a drop of 0.06 V, which is negligible for the load. Above 0.34 A, or as ambient temperature rises, the internal material expands with heat, resistance climbs and the current is limited.

After the fault is cleared

When the part cools after a trip, resistance falls back to the low state and the loop runs again with no manual reset. After one trip the resistance is at most 6.50 Ω, 16 times the 0.40 Ω factory value, which gives 0.91 V at 0.14 A. The 6.50 Ω figure is the limit after repeated trips; check the downstream circuit against it.

Parameters and selection

The full datasheet is available for download on this page, covering the derating table, time-current curves and package dimensions. At 60 °C inside an enclosure the hold current is 0.09 A, and 0.06 A at 85 °C; size the load against those figures. For lot confirmation, stock or an alternative rated above 60 V, contact our sales team.

Selection Notes

1. The step from 0.10 A to 0.14 A buys most of the drop improvement

Current rises 40% from 0.10 A to 0.14 A, while the post-trip resistance limit falls from 15.00 Ω to 6.50 Ω, 57% lower. At their own ratings the drop is 1.50 V on the 0.10 A part and 0.91 V here. One step further, the 0.20 A part brings the limit to 6.00 Ω, only 8% below this one. Where a little more current is needed and drop matters, this is the step to take.

2. 43% of rating remains at 85 °C

The 0.14 A rating applies at 23 °C. At 85 °C the hold current is 0.06 A, 43% of rating, against 30% on the 0.10 A part. At 60 °C this part carries 0.09 A. In a warm enclosure that also needs 60 V, the high-temperature margin here is wider. Read the derating table at the highest enclosure temperature.

3. Going above 60 V need not cost resistance

Bourns stops at 60 V in this current class. Joincircuit builds 0.14 A parts at 33 V, 60 V, 72 V and 90 V, and the 90 V version carries the same 6.50 Ω post-trip limit. Where the rail exceeds 60 V, the drop does not have to be recalculated after the change. Interrupt rating and derating curves still need checking in the datasheet.