1.10 A hold current, 16 V maximum voltage, 1812 (4532) package. 100 A interrupt rating, 0.21 Ω post-trip. It raises the
The MF-MSMF110/16-2 is a 1812 surface-mount resettable fuse that carries 1.10 A continuously and withstands 16 V maximum. It measures 4.5 × 3.2 mm, has gold-plated terminals and suits reflow soldering. UL, CSA and TÜV recognised, RoHS compliant. The 16 after the slash is the voltage rating, more than twice that of the 1.10 A MF-MSMF110-2; commonly used on boards fed from a 12 V supply, on USB power outlets and on small motors.
| Parameter | Value |
| Hold current | 1.1 A |
| Trip current | 2.2 A |
| Maximum voltage | 16 V |
| Maximum fault current | 100 A |
| Initial resistance | 0.04 Ω |
| Post-trip max resistance | 0.21 Ω |
| Trip current / time | 8 A / 0.3 s |
| Dissipated power | 0.8 W |
| Package | 1812 SMD (4532 mm) |
| -40℃ | -20℃ | 0℃ | 23℃ | 40℃ | 50℃ | 60℃ | 70℃ | 85℃ | |
| Hold current (A) | 1.59 | 1.43 | 1.26 | 1.1 | 0.95 | 0.87 | 0.8 | 0.71 | 0.6 |
| Share of 23 °C rating | 145% | 130% | 115% | 100% | 86% | 79% | 73% | 65% | 55% |
| Model | Vmax | R1max | Package | Note |
| MF-MSMF110 | 6 V | 0.21 Ω | 1812 SMD (4532 mm) | |
| MF-MSMF110/24X | 24 V | 0.18 Ω | 1812 SMD (4532 mm) |
The MF-MSMF110/16-2 is a polymer resettable fuse connected in series between a supply and its load. At 1.10 A it suits small motors, solenoid valves and lamp groups. Above 2.20 A the internal material expands with heat, resistance rises and the current is held to a low value. Once the fault is cleared and the part cools it conducts again, so no board comes out for rework.
1812 package, 4532 in metric, 4.5 mm long, 3.2 mm wide and 0.75 mm high. Gold-plated terminals, black body, model code and production lot marked on top. The 6 V version at the same current, MF-MSMF110-2, fits the same footprint and cannot be told apart by size, so check the voltage on the reel label at goods-in.
It sits in series in the loop. At 23 °C and 1.10 A its own resistance is 0.04 Ω, which gives a drop of 0.04 V, 0.8% of a 5 V supply. Above 2.20 A, or as ambient temperature rises, the internal material expands with heat, resistance climbs and the current is limited. At 8 A it opens within 0.30 s.
When the part cools after a trip, resistance falls back to the low state and the loop runs again with no manual reset. After one trip the resistance is at most 0.21 Ω, five times the 0.04 Ω factory value, which gives 0.23 V at 1.10 A. On a 5 V supply that 0.23 V costs 4.6%; check that the downstream circuit still works.
The full datasheet is available for download on this page and covers the derating table, time-current curves and package dimensions. At 60 °C inside an enclosure the hold current is 0.80 A, and 0.60 A at 85 °C; read the table at the highest enclosure temperature. A nominal 12 V supply reaches 12.6 V, so check the margin against that figure. For lot confirmation or a comparison with the 6 V part, contact our sales team.
The 6 V part suits a 5 V supply only; a regulated 12 V supply reaches 12.6 V, more than twice its rating, and the part breaks down on power-up. A 12 V lead-acid battery reaches 14.4 V, which leaves 1.6 V below the 16 V ceiling, so a battery loop needs transient clamping ahead of the fuse. Use this part behind an adapter; above 16 V go to the 24 V version.
A new part measures 0.04 Ω, which gives 0.04 V at 1.10 A. The post-trip limit is 0.21 Ω, which gives 0.23 V at the same current. On a 5 V supply that 0.23 V costs 4.6%, so a downstream chip left with 5% of headroom drops into undervoltage reset once the fuse recovers. Allow for the 0.23 V in a 5 V system.
The next step up at 1.10 A is the MF-MSMF110/24X-2, rated 24 V, with an interrupt rating of 20 A, a fifth of this part's. Its factory resistance is also higher, 0.06 Ω against 0.04 Ω, which gives 0.07 V at 1.10 A. Move to it only above 16 V, and confirm the fault current stays within 20 A first.