1.10 A hold current, 24 V maximum voltage, 1812 (4532) package. Its 20 A interrupt rating is the lowest among the 1.10 A
The MF-MSMF110/24X-2 is a 1812 surface-mount resettable fuse that carries 1.10 A continuously and withstands 24 V maximum. It measures 4.5 × 3.2 mm, has gold-plated terminals and suits reflow soldering. UL, CSA and TÜV recognised, RoHS compliant. Commonly used for overcurrent protection on boards fed directly from a 24 V battery, communication ports and automotive auxiliary circuits.
| Parameter | Value |
| Hold current | 1.1 A |
| Trip current | 2.2 A |
| Maximum voltage | 24 V |
| Maximum fault current | 20 A |
| Initial resistance | 0.06 Ω |
| Post-trip max resistance | 0.18 Ω |
| Trip current / time | 8 A / 0.5 s |
| Dissipated power | 0.8 W |
| Package | 1812 SMD (4532 mm) |
| -40℃ | -20℃ | 0℃ | 23℃ | 40℃ | 50℃ | 60℃ | 70℃ | 85℃ | |
| Hold current (A) | 2 | 1.7 | 1.4 | 1.1 | 0.95 | 0.88 | 0.8 | 0.73 | 0.61 |
| Share of 23 °C rating | 182% | 155% | 127% | 100% | 86% | 80% | 73% | 66% | 55% |
| Model | Vmax | R1max | Package | Note |
| MF-MSMF110 | 6 V | 0.21 Ω | 1812 SMD (4532 mm) | |
| MF-MSMF110/16 | 16 V | 0.21 Ω | 1812 SMD (4532 mm) |
The MF-MSMF110/24X-2 is a polymer resettable fuse connected in series to limit circuit current. Above 2.20 A the internal resistance rises and holds the loop current to a low value. Once the fault is cleared and the part cools, it conducts again, so the board stays in service. At 1.10 A it suits communication ports and medium-power modules.
1812 package, 4532 in metric, 4.5 mm long, 3.2 mm wide and 0.75 mm high. Gold-plated terminals, black body, model code and production lot marked on top. The 6 V and 16 V versions at 1.10 A fit the same footprint and cannot be told apart by size, so confirm the 24X suffix on the reel label at goods-in.
It sits in series in the loop. At 23 °C and 1.10 A its own resistance is 0.06 Ω, which gives a drop of 0.07 V, or 1.4% of a 5 V rail. Above 2.20 A, or as ambient temperature rises, the internal material expands with heat, resistance climbs and the current is limited.
When the part cools after a trip, resistance falls back to the low state and the loop runs again with no manual reset. After one trip the resistance is at most 0.18 Ω, 3 times the 0.06 Ω factory value, which gives 0.20 V at 1.10 A. The 0.18 Ω figure is the limit after repeated trips; check the downstream circuit against it.
The full datasheet is available for download on this page and covers the derating table, time-current curves and package dimensions. In a fault this part clears at most 20 A, so a loop whose short-circuit current is higher needs other handling. For lot confirmation, stock or a 24 V alternative in the same class, contact our sales team.
In a fault this part clears at most 20 A, where the 0.75 A part in the same 24 V group clears 40 A. On a board fed straight from a battery, with a short low-resistance path to the fault, the short-circuit current often exceeds 20 A. Above that figure the part can burn into a conductive path while opening and the downstream circuit is left unprotected. Measure the loop's maximum short-circuit current first; above 20 A put a one-time fuse ahead of it, or keep the load under 0.75 A and use the MF-MSMF075/24-2.
The 1.10 A rating applies at 23 °C. At 60 °C the hold current falls to 0.80 A, and at 85 °C to 0.61 A. A board drawing 1 A passes on the bench and opens by itself once it sits in an 85 °C enclosure. Read the derating table at the highest enclosure temperature and keep the load below that figure.
A fully charged 24 V battery reaches 28.8 V, which is above this part's 24 V ceiling. Sustained operation above the ceiling degrades the internal material, resistance drifts upwards and the part can eventually burn through. Check the charge cut-off voltage of the supply; where it exceeds 24 V, regulate or clamp ahead of the part, for example with a TVS diode, or move to a part with a higher voltage rating.