≡ Param Finder by package / current / voltage
伯恩斯MF-MSMF110/24X-2 自恢复保险丝 1.10A 24V 1812封装
上一张
  • 伯恩斯MF-MSMF110/24X-2 自恢复保险丝 1.10A 24V 1812封装
下一张

Bourns MF-MSMF110/24X-2 Resettable Fuse 1.10A 24V 1812

1.10 A hold current, 24 V maximum voltage, 1812 (4532) package. Its 20 A interrupt rating is the lowest among the 1.10 A

Download

0

The MF-MSMF110/24X-2 is a 1812 surface-mount resettable fuse that carries 1.10 A continuously and withstands 24 V maximum. It measures 4.5 × 3.2 mm, has gold-plated terminals and suits reflow soldering. UL, CSA and TÜV recognised, RoHS compliant. Commonly used for overcurrent protection on boards fed directly from a 24 V battery, communication ports and automotive auxiliary circuits.

Brand:BOURNS (Joincircuit is an authorised distributor)
Category:Resettable fuse / SMD, 1812 SMD (4532 mm)
Voltage:24 V; Current:hold 1.1 A; trip 2.2 A.

Specifications

ParameterValue
Hold current1.1 A
Trip current2.2 A
Maximum voltage24 V
Maximum fault current20 A
Initial resistance0.06 Ω
Post-trip max resistance0.18 Ω
Trip current / time8 A / 0.5 s
Dissipated power0.8 W
Package1812 SMD (4532 mm)

Temperature Derating

-40℃-20℃0℃23℃40℃50℃60℃70℃85℃
Hold current (A)21.71.41.10.950.880.80.730.61
Share of 23 °C rating182%155%127%100%86%80%73%66%55%

Same-Package Alternatives

ModelVmaxR1maxPackageNote
MF-MSMF1106 V0.21 Ω1812 SMD (4532 mm)
MF-MSMF110/1616 V0.21 Ω1812 SMD (4532 mm)

Product Description

What this product is

The MF-MSMF110/24X-2 is a polymer resettable fuse connected in series to limit circuit current. Above 2.20 A the internal resistance rises and holds the loop current to a low value. Once the fault is cleared and the part cools, it conducts again, so the board stays in service. At 1.10 A it suits communication ports and medium-power modules.

Dimensions and appearance

1812 package, 4532 in metric, 4.5 mm long, 3.2 mm wide and 0.75 mm high. Gold-plated terminals, black body, model code and production lot marked on top. The 6 V and 16 V versions at 1.10 A fit the same footprint and cannot be told apart by size, so confirm the 24X suffix on the reel label at goods-in.

How it works

It sits in series in the loop. At 23 °C and 1.10 A its own resistance is 0.06 Ω, which gives a drop of 0.07 V, or 1.4% of a 5 V rail. Above 2.20 A, or as ambient temperature rises, the internal material expands with heat, resistance climbs and the current is limited.

After the fault is cleared

When the part cools after a trip, resistance falls back to the low state and the loop runs again with no manual reset. After one trip the resistance is at most 0.18 Ω, 3 times the 0.06 Ω factory value, which gives 0.20 V at 1.10 A. The 0.18 Ω figure is the limit after repeated trips; check the downstream circuit against it.

Parameters and selection

The full datasheet is available for download on this page and covers the derating table, time-current curves and package dimensions. In a fault this part clears at most 20 A, so a loop whose short-circuit current is higher needs other handling. For lot confirmation, stock or a 24 V alternative in the same class, contact our sales team.

Selection Notes

1. 20 A is the lowest fault-current limit in the 24 V group

In a fault this part clears at most 20 A, where the 0.75 A part in the same 24 V group clears 40 A. On a board fed straight from a battery, with a short low-resistance path to the fault, the short-circuit current often exceeds 20 A. Above that figure the part can burn into a conductive path while opening and the downstream circuit is left unprotected. Measure the loop's maximum short-circuit current first; above 20 A put a one-time fuse ahead of it, or keep the load under 0.75 A and use the MF-MSMF075/24-2.

2. At 85 °C inside an enclosure it carries 0.61 A

The 1.10 A rating applies at 23 °C. At 60 °C the hold current falls to 0.80 A, and at 85 °C to 0.61 A. A board drawing 1 A passes on the bench and opens by itself once it sits in an 85 °C enclosure. Read the derating table at the highest enclosure temperature and keep the load below that figure.

3. The 24 V ceiling sits 4.8 V below a full 24 V battery

A fully charged 24 V battery reaches 28.8 V, which is above this part's 24 V ceiling. Sustained operation above the ceiling degrades the internal material, resistance drifts upwards and the part can eventually burn through. Check the charge cut-off voltage of the supply; where it exceeds 24 V, regulate or clamp ahead of the part, for example with a TVS diode, or move to a part with a higher voltage rating.