≡ Param Finder by package / current / voltage

Hold current 2.00A. Maximum voltage 10V. SM package. For overcurrent protection of 5V mainboards and disk drive supply branches. Post-trip resistance 0.1Ω. Breaking capacity 40A. Automatic recovery after fault removal.

Brand:BOURNS (Joincircuit is an authorised distributor)
Category:Resettable fuse / SMD, SM package
Voltage:10 V; Current:hold 2 A; trip 4 A.

Specifications

ParameterValue
Hold current2 A
Trip current4 A
Maximum voltage10 V
Maximum fault current40 A
Initial resistance0.03 Ω
Post-trip max resistance0.1 Ω
Trip current / time— A / — s
Dissipated power1.1 W
PackageSM package

Same-Package Alternatives

ModelVmaxR1maxPackageNote
MF-SM20015 V0.125 ΩSM package

Selection Notes

1. 10V is the lowest rating in the 2.00A step

A 5V system with 10 percent margin reaches 5.5V, still 4.5V below 10V. A 12V supply can swing above 13V, which breaks down past 10V. For 2.00A on a 12V circuit use MF-SM200 at 15V and 100A. On a board with both 12V and 5V sections, do not put this part on the 12V side.

2. 1.1W dissipation and 0.20V post-trip drop

Fresh resistance is 0.03Ω for 0.06V. After reset the limit is 0.1Ω, or 0.20V. The same-current MF-SM200 is 0.25V, so this part is 0.05V lower. At trip it dissipates only 1.1W, 0.8W less than the 1.9W of SM200. On a densely packed board this part cools better.

3. 40A breaking capacity, less than half of SM200's 100A

Short-circuit current on a 5V mainboard is often between 30A and 60A. This part breaks 40A and the excess relies on upstream protection. No surface-mount part with higher breaking capacity exists for 2.00A at 10V or below. Above 40A of supply-side short-circuit current, add another fuse stage in the circuit.