Hold current 0.05A. Maximum voltage 30V. 1210 package. For overcurrent protection in microamp-level signal circuits. Post-trip resistance 50Ω. Breaking capacity 10A. Recovers automatically after the fault is cleared.
| Parameter | Value |
| Hold current | 0.05 A |
| Trip current | 0.15 A |
| Maximum voltage | 30 V |
| Maximum fault current | 10 A |
| Initial resistance | 2.8 Ω |
| Post-trip max resistance | 50 Ω |
| Trip current / time | — A / — s |
| Dissipated power | 0.6 W |
| Package | 1210 SMD (3225 mm) |
USMF voltage ratings come in three tiers: 30V, 13.2V and 6V. Higher current means a lower tier. All three 30V parts break 10A. This part holds 0.05A and sits in the 30V, 10A tier. Above 10A of circuit short-circuit current, use the 050, which breaks 40A.
50Ω times 0.05A gives a 2.5V drop. That is 50% of a 5V system, leaving only 2.5V at the load. A new part measures 2.8Ω, a 0.14V drop at the same current. This part suits microamp-level signal circuits only.
The 010 holds 0.10A with a 15Ω post-trip resistance limit. At the same 0.05A its drop is 0.75V against 2.5V here. Both are 30V, 10A parts and differ only in current tier and resistance. The 005 is only needed when circuit current stays below 0.05A.