≡ Param Finder by package / current / voltage

Hold current 0.05A. Maximum voltage 30V. 1210 package. For overcurrent protection in microamp-level signal circuits. Post-trip resistance 50Ω. Breaking capacity 10A. Recovers automatically after the fault is cleared.

Brand:BOURNS (Joincircuit is an authorised distributor)
Category:Resettable fuse / SMD, 1210 SMD (3225 mm)
Voltage:30 V; Current:hold 0.05 A; trip 0.15 A.

Specifications

ParameterValue
Hold current0.05 A
Trip current0.15 A
Maximum voltage30 V
Maximum fault current10 A
Initial resistance2.8 Ω
Post-trip max resistance50 Ω
Trip current / time— A / — s
Dissipated power0.6 W
Package1210 SMD (3225 mm)

Selection Notes

1. Smallest current in the 30V tier, breaking capacity only 10A

USMF voltage ratings come in three tiers: 30V, 13.2V and 6V. Higher current means a lower tier. All three 30V parts break 10A. This part holds 0.05A and sits in the 30V, 10A tier. Above 10A of circuit short-circuit current, use the 050, which breaks 40A.

2. 50Ω post-trip, a 2.5V drop in a 5V system

50Ω times 0.05A gives a 2.5V drop. That is 50% of a 5V system, leaving only 2.5V at the load. A new part measures 2.8Ω, a 0.14V drop at the same current. This part suits microamp-level signal circuits only.

3. The 010 has 30% of the resistance and twice the current

The 010 holds 0.10A with a 15Ω post-trip resistance limit. At the same 0.05A its drop is 0.75V against 2.5V here. Both are 30V, 10A parts and differ only in current tier and resistance. The 005 is only needed when circuit current stays below 0.05A.