≡ Param Finder by package / current / voltage

Hold current 0.10A. Maximum voltage 30V. 1210 package. For overcurrent protection in low-current signal circuits. Post-trip resistance 15Ω. Breaking capacity 10A. Recovers automatically after the fault is cleared.

Brand:BOURNS (Joincircuit is an authorised distributor)
Category:Resettable fuse / SMD, 1210 SMD (3225 mm)
Voltage:30 V; Current:hold 0.1 A; trip 0.3 A.

Specifications

ParameterValue
Hold current0.1 A
Trip current0.3 A
Maximum voltage30 V
Maximum fault current10 A
Initial resistance0.8 Ω
Post-trip max resistance15 Ω
Trip current / time— A / — s
Dissipated power0.6 W
Package1210 SMD (3225 mm)

Selection Notes

1. Mid-tier of the 30V, 10A group, the next tier drops to 13.2V

All three parts in the 30V tier break 10A. From the 050 up the rating changes to 13.2V with 40A breaking capacity. This part sits in the middle of the 30V tier. None of the three 30V parts clears a circuit above 10A of short-circuit current.

2. A 1.5V drop, 30% of a 5V system

Post-trip resistance is 15Ω, a 1.5V drop at 0.10A. That is 30% of a 5V system, leaving 3.5V at the load. A new part measures 0.8Ω, a 0.08V drop at the same current. Recalculate any downstream circuit with a minimum operating voltage above 3.5V.

3. The 020 in the same tier is only 5Ω, cutting the drop to 0.5V

The 020 holds 0.20A with a 5Ω post-trip resistance limit. At the same 0.10A its drop is 0.5V. Both are 30V, 10A parts, differing only in current tier and resistance. A 0.10A load is half the 020 hold current, and the drop is two thirds lower.