Hold current 0.10A. Maximum voltage 30V. 1210 package. For overcurrent protection in low-current signal circuits. Post-trip resistance 15Ω. Breaking capacity 10A. Recovers automatically after the fault is cleared.
| Parameter | Value |
| Hold current | 0.1 A |
| Trip current | 0.3 A |
| Maximum voltage | 30 V |
| Maximum fault current | 10 A |
| Initial resistance | 0.8 Ω |
| Post-trip max resistance | 15 Ω |
| Trip current / time | — A / — s |
| Dissipated power | 0.6 W |
| Package | 1210 SMD (3225 mm) |
All three parts in the 30V tier break 10A. From the 050 up the rating changes to 13.2V with 40A breaking capacity. This part sits in the middle of the 30V tier. None of the three 30V parts clears a circuit above 10A of short-circuit current.
Post-trip resistance is 15Ω, a 1.5V drop at 0.10A. That is 30% of a 5V system, leaving 3.5V at the load. A new part measures 0.8Ω, a 0.08V drop at the same current. Recalculate any downstream circuit with a minimum operating voltage above 3.5V.
The 020 holds 0.20A with a 5Ω post-trip resistance limit. At the same 0.10A its drop is 0.5V. Both are 30V, 10A parts, differing only in current tier and resistance. A 0.10A load is half the 020 hold current, and the drop is two thirds lower.