Hold current 0.20A. Maximum voltage 30V. 1210 package. For overcurrent protection in sensor and interface circuits. Post-trip resistance 5Ω. Breaking capacity 10A. Recovers automatically after the fault is cleared.
| Parameter | Value |
| Hold current | 0.2 A |
| Trip current | 0.4 A |
| Maximum voltage | 30 V |
| Maximum fault current | 10 A |
| Initial resistance | 0.4 Ω |
| Post-trip max resistance | 5 Ω |
| Trip current / time | — A / — s |
| Dissipated power | 0.6 W |
| Package | 1210 SMD (3225 mm) |
USMF voltage ratings come in three tiers: 30V, 13.2V and 6V. The 30V tier goes up to 0.20A. To reach 0.50A you accept a 13.2V limit. Higher current tiers carry lower voltage ratings, and the two do not move together.
A new part measures 0.4Ω, a 0.08V drop at 0.20A. Post-trip resistance is 5Ω, a 1.0V drop at the same current. That is 20% of a 5V system, leaving 4.0V at the load. A circuit that recovers after a trip has to be rechecked at 1.0V.
The 050 holds 0.50A with 0.9Ω post-trip resistance. At the same 0.20A its drop is 0.18V against 1.0V here. Its breaking capacity is 40A, four times this part. For a 12V system with high short-circuit current, take the 050.