≡ Param Finder by package / current / voltage

Hold current 0.50A. Maximum voltage 13.2V. 1210 package. For overcurrent protection on branch circuits in 12V lead-acid battery equipment. Post-trip resistance 0.9Ω. Breaking capacity 40A. Recovers automatically after the fault is cleared.

Brand:BOURNS (Joincircuit is an authorised distributor)
Category:Resettable fuse / SMD, 1210 SMD (3225 mm)
Voltage:13.2 V; Current:hold 0.5 A; trip 1 A.

Specifications

ParameterValue
Hold current0.5 A
Trip current1 A
Maximum voltage13.2 V
Maximum fault current40 A
Initial resistance0.18 Ω
Post-trip max resistance0.9 Ω
Trip current / time— A / — s
Dissipated power0.6 W
Package1210 SMD (3225 mm)

Selection Notes

1. A 13.2V rating against the full-charge voltage of a 12V lead-acid battery

The 13.2V tier is the middle level in USMF. The tier below, 6V, only covers 5V circuits. The tier above, 30V, breaks only 10A. This is the only part at 0.50A, with no other voltage rating to choose.

2. A 0.45V drop, 3.8% of a 12V system

Post-trip resistance is 0.9Ω, a 0.45V drop at 0.50A. That is 3.8% of a 12V system and 9% of a 5V system. A new part measures 0.18Ω, a 0.09V drop at the same current; post-trip resistance is 5 times the new part.

3. The 020 rates 16.8V higher and drops only 0.18V

The 020 holds 0.20A, rated 30V with 10A breaking capacity. At the same 0.50A its drop is 0.18V, and this part is 2.5 times that. Above 10A of system short-circuit current the 020 is no substitute.

Up Page:

Next Page: