Hold current 0.50A. Maximum voltage 13.2V. 1210 package. For overcurrent protection on branch circuits in 12V lead-acid battery equipment. Post-trip resistance 0.9Ω. Breaking capacity 40A. Recovers automatically after the fault is cleared.
| Parameter | Value |
| Hold current | 0.5 A |
| Trip current | 1 A |
| Maximum voltage | 13.2 V |
| Maximum fault current | 40 A |
| Initial resistance | 0.18 Ω |
| Post-trip max resistance | 0.9 Ω |
| Trip current / time | — A / — s |
| Dissipated power | 0.6 W |
| Package | 1210 SMD (3225 mm) |
The 13.2V tier is the middle level in USMF. The tier below, 6V, only covers 5V circuits. The tier above, 30V, breaks only 10A. This is the only part at 0.50A, with no other voltage rating to choose.
Post-trip resistance is 0.9Ω, a 0.45V drop at 0.50A. That is 3.8% of a 12V system and 9% of a 5V system. A new part measures 0.18Ω, a 0.09V drop at the same current; post-trip resistance is 5 times the new part.
The 020 holds 0.20A, rated 30V with 10A breaking capacity. At the same 0.50A its drop is 0.18V, and this part is 2.5 times that. Above 10A of system short-circuit current the 020 is no substitute.