Hold current 1.10A. Maximum voltage 6V. 1210 package. For overcurrent protection on 5V supply branches. Post-trip resistance 0.21Ω. Breaking capacity 40A. Recovers automatically after the fault is cleared.
| Parameter | Value |
| Hold current | 1.1 A |
| Trip current | 2.2 A |
| Maximum voltage | 6 V |
| Maximum fault current | 40 A |
| Initial resistance | 0.05 Ω |
| Post-trip max resistance | 0.21 Ω |
| Trip current / time | — A / — s |
| Dissipated power | 0.6 W |
| Package | 1210 SMD (3225 mm) |
The 6V tier holds only the 110 and the 150, both breaking 40A, four times the 30V tier. The 6V limit keeps system voltage at 5V, so neither part works on a 12V circuit.
Post-trip resistance is 0.21Ω, a 0.231V drop at 1.10A. That is 4.6% of a 5V system, leaving 4.77V at the load. A new part measures 0.05Ω, a 0.055V drop at the same current.
The 150 holds 1.50A with 0.11Ω post-trip resistance. Both are 6V, 40A parts, differing in current tier and resistance. For a 1.10A load take the 110, which trips at 2.20A. The 150 trips at 3.00A, 0.80A higher.