SMD Fuse Selection and Application Scope

SMD fuses are divided into resettable SMD fuses and one-time SMD fuses, and they are used very widely in everyday life: the type is chosen to match the performance each product requires, and their main applications are digital cameras, notebooks, mobile phones and other electronic products. From the traditional glass-tube fuse to the miniature fuse and on to SMD fuses, because manufacturing processes differ, the selection criteria differ as well. This article explains the factors that can affect the choice of an SMD fuse.
 
 
First: product certification. Products intended for export, for example to North America, must carry UL or CSA approval, and goods shipped to Europe must also comply with the EU RoHS Directive, that is, the environmental certification commonly referred to as SGS.
 
 
Second: the normal operating current of the circuit. In service, the current passing through the fuse should not exceed 75% of its rated current.
 
 
Third: the voltage applied across the fuse. SMD fuses are normally used in portable equipment, where the circuit voltage is generally low; as long as the rated voltage of the SMD fuse is higher than the circuit voltage, it can be selected with confidence. (Related reading: Protecting solar insect-killer lamps with resettable fuses)
 
 
Fourth: the ambient temperature of the fuse. Where an SMD fuse is used in portable equipment, the temperature rise of the fuse has to be taken into account, that is, its rated current must be derated. The fuse must work within its specified temperature range; once the ambient temperature around the fuse exceeds 25°C, the temperature derating curve should be applied.
 
 
Fifth: the magnitude of the overload current in the circuit, and how long that overload lasts, both at minimum and at maximum. Judging an overload current usually calls for a combination of oscilloscope measurement and theoretical calculation. The basic requirement for a fuse is that it must not open when it should not, for example during an inrush current, and that it must open within a suitable time when it should, for example when an overload current has to be interrupted.
 
 
Sixth: resistance. The resistance of an SMD fuse affects certain circuits: if a fuse with too high an internal resistance is fitted in such a circuit, it will disturb the circuit parameters and the circuit will not work properly. (Recommended reading: Correct installation and handling of household fuses)
 
 
Seventh: pulses, shock currents, surge currents, starting currents and circuit transients. This point deserves particular attention with SMD fuses: because of the process limitations imposed by their small size, the surge withstand of an SMD fuse is far lower than that of a glass-tube fuse or any other larger fuse of the same rated current. (For reference only)
 
 
These seven points summarise the main considerations when selecting an SMD fuse, together with the scope of application of SMD fuses. If anything remains unclear or you have further questions, leave a message on our Contact Us page and we will reply as soon as possible.